This paper presents a simple algorithm for estimation of the rotor position. The injected high frequency voltage is a sinusoidal
voltage and is injected into the stator of a motor. An interior permanent magnet synchronous motor (IPMSM) has spatial saliency
because the d-axis inductance and q-axis inductance are different from each other. The injected high frequency voltage is influenced
by saliency. Therefore, the rotor position is included in the stator current of the motor. The rotor position is estimated using filters
but the estimated rotor position has error due to the time delay. Therefore, the proposed method decreases the number of filters
and uses different synchronous reference frame transformation (SFT) to extract the rotor position error between the estimated value
and actual value. The simulation and experimental results present the effectiveness of the proposed method by showing waveforms
of the rotor speed and position with load conditions.