This paper presents a new and simple method for sensorless control of matrix converter drives using a power flowing to the
motor. The proposed control algorithm is based on controlling the instantaneous real and imaginary powers into the induction
motor. To improve low-speed sensorless performance, the non-linearities of a matrix converter drive such as commutation
delays, turn-on and turn-off times of switching devices, and on-state switching device voltage drop are modelled using a PQ-
power transformation and compensated using a reference power control scheme. The proposed sensorless control method is
applied for the induction motor drive using a 3 kW matrix converter system. Experimental results are shown to illustrate the
feasibility of the proposed strategy.