This paper presents a high-frequency cable modeling in industrial inverter systems with long transmission lines. Cable modeling considering high frequency reflects dielectric losses, proximity effects, and skin effects. The accurate modeling of long transmission lines considering high-frequency serves as a basis for addressing issues such as overvoltage. The validity and effectiveness of the improved cable modeling are verified through simulation results.