This paper suggests a cascade output voltage regulation strategy for dc/dc boost converters that embeds a robust inner-loop current
controller against parameter variations. The contributions of this paper are divided into two parts. The first contribution is to present
a simple and robust inner-loop current controller despite parameter uncertainties, guaranteeing the stability of the whole closed-
loop system including the first-order internal dynamics. The second contribution is to show that an outer-loop proportional–integral
regulator can stabilize the output voltage error without relying on any parameter information. Simulations and experiments using a
3-kW dc/dc boost converter showed that the proposed method offers satisfactory closed-loop performance in the presence of
parameter uncertainties.