PUBLICATIONS

Paper

[International Journals] Hyung-Seop Kim, Won-Sang Im, Jang-Mok Kim, Dong-Choon Lee, and Kyo-Beum Lee, “Fault Diagnosis Method of Voltage Sensor in 3-phase AC/DC PWM Converters,” Journal of International Conference on Electrical Machines and Systems, vol. 1, no. 3, pp. 115–121, Sep. 2012.

  • 글쓴이 관리자
  • 날짜 2019-06-30 15:04
  • 조회 1,745

This paper proposes a fault diagnosis method of the line-to-line voltage sensors in 3- phase AC/DC pulse width modulation (PWM)

converters. The line-to-line voltage sensors are an essential device to obtain the information of the grid voltages for controlling the

3-phase AC/DC PWM converters. If the line-to-line voltage sensors are mismeasured by various faults, the voltage sensors can obtain

wrong information of the grid voltage. It has an adverse effect on the control of the converter. Therefore, the converter causes the

unbalance input AC current and the DC-link voltage ripple in the 3-phase AC/DC PWM converter. Hence, fast fault detection and

fault tolerant control are needed. In this paper, the fault diagnosis method is proposed and verified through simulations and

experiments. 