PUBLICATIONS

Paper

[International Conference] Hyun-Woo Sim, June-Seok Lee, and Kyo-Beum Lee, "A Detection Method for an Open-Switch Fault in Cascaded H-bridge Multilevel Inverters," in Proc. ECCE Conf., Sep. 2014, pp. 2101–2106.

  • 글쓴이 관리자
  • 날짜 2019-06-28 19:42
  • 조회 1,377

This paper presents a detecting method for an open-switch fault in cascaded H-bridge multilevel inverters. Recently, cascaded

multilevel inverters are widely used in high voltage and power systems. Therefore, the reliability of this topology has become an

important factor. To improve the reliability, detecting methods for an open-switch fault are required. The proposed method is based

on the current path analysis according to zero voltage switching states when the open-switch fault occurs. The location of both faulty

cells and switches can be detected by the current waveform and zero voltage switching states. This method is applicable when using

the level-shifted PWM that is commonly used for a modulation method in cascaded H-bridge multilevel inverters. The performance

of proposed fault detecting method is verified by simulation results.